2018-11-14Ist2386PartV-1191911 Indian Standard METHODS OF TEST . FOR AGGREGATES FOR COWCRETE PART V SOUNDNESS 0. FOREWORD 0.1 This IndianStandard Part V was adopted by the Indian Standards Institution on 13 September 1963 after the draft finalied by the Cement

Get Price ListChat Online

News List

  • Cbr Test Procedure  California Bearing Ratio For

    Cbr Test Procedure California Bearing Ratio For

    It is the ratio of force per unit area required to penetrate a soil mass with standard circular piston at the rate of 1.25 mmmin. to that required for the corresponding penetration of a standard material. The California Bearing Ratio Test CBR Test is a penetration test developed by California State Highway Department U.S.A. for evaluating the bearing capacity of subgrade soil for design

  • Sieve Analysis Of Soil Its Determination Theory

    Sieve Analysis Of Soil Its Determination Theory

    2020-6-8Theory. In practice each fraction contains particles between definite limits these being the openings of standard test sieves. Before sieving the soil should be air dried in order to avoid lumps of fine particles and also to prevent clogging of the finer sieves

  • Concrete Slump Test Procedure Applications Types

    Concrete Slump Test Procedure Applications Types

    A slump test is a method used to determine the consistency of concrete. The consistency or stiffness indicates how much water has been used in the mix. The stiffness of the concrete mix should be matched to the requirements for the finished product quality. Slump is a measurement of concretes workability or fluidity. Its an indirect measurement of concrete

  • On Aggregate Grading  Nrmca Expanding The Concrete

    On Aggregate Grading Nrmca Expanding The Concrete

    2009-1-28ASTM C39 and drying shrinkage per ASTM C157 with the exception that specimens were moist-cured for 7 days and then stored at 50 relative humidity for 28 days. version of ASTM C1610 and finishability tests on specimens in our lab. Details of the nonstandardied tests and deviations from ASTM standards are provided in Reference 15

  • Field Sampling And Testing Manual Section 200

    Field Sampling And Testing Manual Section 200

    2019-3-26per 200000 C.Y. ND T 27 Sieve Analysis of Fine and Coarse Aggregates Minimum 1 test result per project. ND T 11 Materials Finer Than No. 200 Sieve in Mineral Aggregates by Washing Minimum 1 test result per project. NDDOT 4 Percentage of Fracture Particles in Coarse Aggregate Minimum 1 test result per project

  • 04 Standard Test Methods For Selfcompacting Concrete

    04 Standard Test Methods For Selfcompacting Concrete

    2008-5-30This standard covers the test method for slump flow of self-compacting concrete with a maximum coarse aggregate sie of 40 mm or less. 2. Apparatus 2.1 A slump cone specified in JIS A 1101 Method of test for slump of concrete shall be used. 2.2 The plate1 shall be made of steel and sufficiently watertight and rigid. It shall be

  • Full Text Of Is 383 Specification For Coarse And Fine

    Full Text Of Is 383 Specification For Coarse And Fine

    Full text of IS 383 Specification for Coarse and Fine Aggregates From Natural Sources For Concrete See other formats iS Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citiens to secure access to information under the control of public authorities in

  • Laboratory Testing  Statens Vegvesen

    Laboratory Testing Statens Vegvesen

    2014-3-4Tests on Aggregates and Concrete 2.1 Moisture Content of Aggregates BS812Part 1091990 2.2 Relative Density and Water Absorption BS812Part 21975 2.3 Sieve Tests on Aggregates BS812Part 103.11985 2.4 Flakiness Index FI and Average Least Dimension ALD BS812Section 105.11989 2.5 Elongation Index BS812Section 105.21990

  • Indian Railway Standard Specification For Pre

    Indian Railway Standard Specification For Pre

    2019-10-17INDIAN RAILWAY STANDARD SPECIFICATION FOR PRE-TENSIONED PRESTRESSED CONCRETE SLEEPERS FOR BROAD GAUGE AND METRE GAUGE SERIAL NO. T-39 FIFTH REVISION February 2016 RESEARCH DESIGNS AND STANDARDS ORGANISATION 0.4.2 Additional relevant tests on aggregates have been added for use of crushed stone sand as fine

  • A Study On Stripping Of Coarse Aggregates Of Andhra

    A Study On Stripping Of Coarse Aggregates Of Andhra

    2020-4-202.1.1 Test as per Indian Standard Method of Test for Determination of Stripping Value of Road Aggregates IS 6241-1971 is the standard describing the stripping test for the coarse aggregate. 2.2 Tests under Varying Conditions In this study testing is performed on the aggregate-bitumen

  • Technical Specification Volume Ii Contents

    Technical Specification Volume Ii Contents

    2014-6-261727 -1967 Methods of tests for poolanic materials 2250 -1981 Code of practice for preparation and use of masonry mortar. Reaffirm- 1990 2386 -1963 Methods of Test for Aggregates for Concrete 2386 Pt.I-1 963 Particle sie and shape 2386 Pt. II-1963 Estimation of deleterious materials and organic impurities

  • Bureau Of Indian Standards

    Bureau Of Indian Standards

    2018-12-10Tests j For product characteristic requiring testing time 30 days one month and above like keeping property tests in paints carbon paper insulating tapes various types of inks etc evidence of conformity in the form of test reports from any laboratory firms own or outside as per 4 e above should be made available for such tests

  • Quality Assurance Handbook For Rural Roads

    Quality Assurance Handbook For Rural Roads

    2018-5-16Quality Assurance Handbook for Rural Roads Quality Management System and Quality Control Requirements May 2007. Indian Roads Congress Kamakoti Marg Sector-6 R.K. Puram New Delhi-110022 frequency of tests indicated that there is

  • Building Material Testing Lab  Road Material Testing

    Building Material Testing Lab Road Material Testing

    2019-9-27Standard Testing Laboratories is the one of the Best Testing Laboratories in Delhi NCR India. Standard Testing Lab provides Best Testing Services in field Building material Testing and Road Material Testing and insure about qualities

  • How Do We Check The Quality Of Coarse Aggregates For

    How Do We Check The Quality Of Coarse Aggregates For

    In such a case you have to test the coarse aggregate of stone aggregates as per procedure laid down in Bureau of Indian Code no IS 2386-PART II for the following parameters and check up whether such coarse aggregates quality is as per norms spec

  • Specific Gravity Of Coarse Aggregates Its Importance

    Specific Gravity Of Coarse Aggregates Its Importance

    2020-6-8As per the definition given in the IS 2386 Part III 1963 Indian Standard- Methods of Test for Aggregates for Concrete Specific Gravity Density Voids Absorption and Bulking the specific gravity of coarse aggregates is the weight of the aggregates dried to constant weight in an oven at 100C divided by its absolute volume including the natural voids within the aggregate

  • The Frequency Of Various Tests  Quality Engineer Guide

    The Frequency Of Various Tests Quality Engineer Guide

    2020-5-29In the first stage of construction the first test shall be taken is the In-Situ Density test but I was a bit stock when the consultant asked about the frequency of compaction test of in-situ soil. I made a research immediately just within the contract project documents specification drawing bill of quantity but most often it is written on the specification sometimes it is also written in

  • M Sand Is Codes  Construction Materials In India

    M Sand Is Codes Construction Materials In India

    Tags sand IS-code plastering sand M Sand Indian Standard codes. concrete sand M Sand or Manufactured sand is an Eco-friendly economical alternative for river sand which has become widely popular for use in all constructional purposes

  • Sieve Analysis Particle Sie Analysis Procedure  Basic

    Sieve Analysis Particle Sie Analysis Procedure Basic

    Methods Of Sieve Sie Analysis Determination of article sie is more important in Civil Engineering as the particle sie determines the effectiveness of final product. The characters of particle such as bulk density physical stability permeability and many more are decided by its sie. To determine the sie distribution of particles the sieve analysis test procedure is an effective method

  • Manual For Frequency Of Sampling And Testing

    Manual For Frequency Of Sampling And Testing

    2015-10-21SAMPLING AND TESTING AND BASIS FOR USE OF MATERIALS GENERAL The Department Standard Specifications Section 106.02 states that the minimum required number of samples and tests will be as set out in the Frequency Manual. This edition of the Frequency Manual was prepared to make the frequency of sampling and testing conform to the

  • Flakiness Index And Elongation Index Test On Coarse

    Flakiness Index And Elongation Index Test On Coarse

    2020-6-7A standard thickness gauge A standard length gauge IS sieves of sies 63 50 40 31.5 25 20 16 12.510 and 6.3mm A balance of capacity 5kg readable and accurate up to 1 gm. Theory of Flakiness Index and Elongation Index Tests. The particle shape of aggregates is determined by the percentages of flaky and elongated particles contained in it

  • Road Standards And Paving Standards  Astm

    Road Standards And Paving Standards Astm

    Standard Test Method for Nonrepetitive Static Plate Load Tests of Soils and Flexible Pavement Components for Use in Evaluation and Design of Airport and Highway Pavements D4602 - 932015 Standard Guide for Nondestructive Testing of Pavements

  • 5 Aggregate Specifications And Requirements  Ingov

    5 Aggregate Specifications And Requirements Ingov

    2012-4-9Aggregates used for stone matrix asphalt mixtures are required to meet the requirements of AS aggregates in accordance with Section 904.03 a. These requirements include testing with the Micro-Deval abrasion apparatus AASHTO T 327 and determination of the aggregate degradation in accordance with ITM 220. Additional requirements for . . . in

  • Manual On Concrete Laboratory

    Manual On Concrete Laboratory

    2018-6-25standard 90 micron IS sieve. 2. Break down any air-set lumps in the cement sample with fingers. 3. Agitate the sieve by giving swirling planetary and linear movements for a period of 10 minutes or until no more fine material passes through it. 4. Collect the residue left on the sieve using brush if necessary and weigh the residue. 5